Delta · Ultron DPS
The Delta Ultron DPS is a large three-phase UPS rated 300 to 1,200 kVA.

Delta lists the Ultron DPS as a current range.
Sources, checked October 3, 2026: Delta, DPS 300-1200 kVA.
How a three phase double conversion UPS carries the load, and where the bypass sits.
The orderable configurations we supply and service:
| Model | Rating | Phase / Voltage | Part number | Status |
|---|---|---|---|---|
| Delta Ultron DPS-300K (300kVA) | 300 kW | 3ph 4-wire+G in/out 220/380-240/415V | DPS-300K | Current |
| Delta Ultron DPS-400K (400kVA) | 400 kW | 3ph 4-wire+G in/out 220/380-240/415V | DPS-400K | Current |
| Delta Ultron DPS-500K (500kVA) | 500 kW | 3ph 4-wire+G in/out 220/380-240/415V | DPS-500K | Current |
| Delta Ultron DPS-600K (600kVA) | 600 kW | 3ph 4-wire+G in/out 220/380-240/415V | DPS-600K | Current |
| Delta Ultron DPS-800K (800kVA) | 800 kW | 3ph 4-wire+G in/out 220/380-240/415V | DPS-800K | Current |
| Delta Ultron DPS-1000K (1000kVA) | 1000 kW | 3ph 4-wire+G in/out 220/380-240/415V | DPS-1000K | Current |
| Delta Ultron DPS-1200K (1200kVA) | 1200 kW | 3ph 4-wire+G in/out 220/380-240/415V | DPS-1200K | Current |
The Ultron DPS is a monolithic three-phase UPS from 300 to 1200 kVA in a single unit, with unity output power factor (kW = kVA) and AC-AC efficiency up to 96.5% and 99% in ECO mode. It parallels up to 8 units to deliver up to 10 MW for large data centres and colocations. Key components self-detect with a pre-warning function, it's fully front-access to shorten repair time, and a 10-inch local display plus optional battery-management software supports predictive maintenance.
Source: Delta, Ultron DPS product page and features. Figures are Delta's published specifications.
Battery strings and cabinets depend on the configuration and runtime. A worn string in the Delta Ultron DPS can be rebuilt from the UPS battery block catalogue.
We service the Delta Ultron DPS across Canada: preventive maintenance, battery replacement and emergency repair, including units the manufacturer no longer supports. We are a Canadian UPS service and supply provider, working on three-phase systems since 2012.
Scheduled visits, battery work and fault response for these systems are covered by Delta UPS maintenance and repair in Canada.
We engineer the solution: load and growth analysis, redundancy (N, N+1, 2N), runtime and battery sizing, paralleling and switchgear, and custom configurations where the standard catalogue doesn't fit. Because we supply every major brand, the Ultron DPS is one option we weigh on its merits, not the only answer.
The Delta Ultron DPS is a large three-phase UPS rated 300 to 1,200 kVA.
No. Delta lists the Ultron DPS as a current range.
A Canadian UPS service and supply provider, in business since 2012, services the Delta Ultron DPS across Canada: preventive maintenance, battery replacement and emergency repair, including discontinued units. Call 1 (438) 881-3363 or email info@threephaseups.ca.