Three-phase UPS service and engineering
We maintain, repair and re-battery UPS systems of every major brand, from rack units to three-phase systems of several hundred kVA, and size new systems to your load and runtime. We reply and quote within 4 business hours.

Nine services cover a UPS from installation to replacement, on every major brand.
We dispatch 24/7 when a UPS drops to bypass, raises an alarm it cannot clear or shuts down.
A preventive maintenance visit tests the UPS under its real load, once or twice a year, and ends with a written report.
Every UPS repair starts with the event log and ends with a written answer on whether the unit is worth fixing.
We replace VRLA strings, battery cabinets and lithium-ion systems on site, and test the new string before we leave.
We survey the site, place and terminate the UPS, and hand it over tested and documented.
A load-bank test proves the UPS at its rated power on a controlled artificial load, without risking the equipment it protects.
A maintenance contract fixes the response time before anything breaks, for one UPS or a fleet across Canada.
We check each unit's lifecycle status, keep older systems running, and plan the replacement before parts run out.
We bid on tenders, standing offers and multi-year contracts for government, hospitals, school boards and universities.
Enter the load, voltage, runtime and redundancy to get an indicative capacity, battery energy and generator size, with every assumption shown. For new systems we recommend Xtreme Power Conversion (XPC) and Delta, and our engineer confirms the sizing before any quote.
A technician is on site the same day in Montreal, Quebec City, Toronto and Ottawa, and within 24 to 48 hours in the other cities.
Maintenance, repair and batteries for every major three-phase brand, including units the manufacturer no longer supports.
What each alarm means on the major three-phase UPS, what is safe to check, and the engineering behind sizing, redundancy and battery rooms.
A Delta Modulon DPH names its alarms in plain text, such as BAT LOW WARNING; chapter 10 of its manual gives causes and solutions.
The Delta Ultron HPH shows plain alarm messages such as OVERLOAD; a few have an operator fix, like bringing the load below 95%.
On an Eaton 93PM, steady red means an active alarm and flashing red a new one not yet acknowledged. Silence the horn, then open LOGS.
An Eaton 93PS shows its state in four status symbols and two rows of door LEDs; a red alarm symbol needs immediate attention.
On an Eaton Power Xpert 9395, a red lamp is an active alarm and a flashing one a new alarm. Open EVENTS and record them.
The Galaxy VL alarm symbol turns blue, yellow or red, and a module framed in red on the mimic diagram is inoperable or in alarm.
From a single edge room to a multi-megawatt hall, we size, supply, install and maintain the three-phase UPS that protects your IT load, every major brand, matched to your density, redundancy and growth.
Plants, utilities, water, transport and process sites need power protection that tolerates heat, harmonics and rough supplies. We size, supply and install rugged three-phase UPS (transformer-based where galvanic isolation matters) and maintain it for the long haul.
Imaging, operating rooms, labs and critical-care power can't blink. We size, supply, install and maintain three-phase UPS for hospitals and clinics, with the redundancy and service response that critical-care loads demand.
| Manufacturer | Three-phase families |
|---|---|
| ABB | Conceptpower DPA, PCS100, Conceptpower DPA UL, DPA UPScale ST, DPA UPScale RI, DPA 250 S4, MegaFlex DPA |
| APC / Schneider | Easy UPS 3S, Symmetra PX, Galaxy VS, Galaxy VM, Galaxy VX, Galaxy VL, MGE Galaxy 3500 |
| Delta | Ultron HPH, Modulon DPH, Modulon DPH G3, Modulon NH Plus, Ultron DPS, Ultron DPM Gen2, Ultron DPM |
| Eaton | 9355, 93PM, 93PM G2, 93PS, 93E, BladeUPS, 9390 |
| GE | SG Series, SitePro, LP33 Series, LP33 Series II, TLE Series |
| Mitsubishi | 9900B, 9900C, 9900D, 9900A, 9800A, 9700, 9900AEGIS |
| Socomec | MASTERYS GP4, MASTERYS MC, MODULYS GP, MODULYS XM, MODULYS XL, DELPHYS GP, MASTERYS BC+ |
| Toshiba | G9000, 4400, G2020, G8000, 4200FA, 4300, 5000 |
| Tripp Lite | SmartOnline SVTX, SmartOnline SUTX, SmartOnline S3MX, SmartOnline SVX, SmartOnline SUT, SmartOnline S3M, SmartOnline SV |
| Vertiv / Liebert | APM2, APM, EXM, EXM2, EXS, EXL S1, NX |
| Xtreme Power | E91, E90, Li90, M90C, M90Ci, M90U, M90LU |
Tell us the application and we reply within 4 business hours with the sizing, the right system, the installation and a written quote. Three-phase installs usually need a licensed electrician, so let us know if you have one.
Brand names are trademarks of their owners and are used only to identify the equipment we service. We are not the manufacturer and are not affiliated with it.