Mitsubishi 9900CX three-phase UPS

The Mitsubishi Electric 9900CX is a three-phase UPS for cloud, IT and colocation sites rated 1 MW.

Mitsubishi 9900CX three-phase UPS
Phase
3PH
Models
1
Lifecycle
Current model

Mitsubishi Electric 9900CX: key facts

Mitsubishi Electric lists the 9900CX as current.

Sources, checked October 3, 2026: Mitsubishi Electric, 9900CX.

THREE PHASE POWER PATH3 PHASE INPUT480 V or 208 V feedRECTIFIERAC to DCDC BUSregulatedINVERTERDC to clean ACCRITICAL LOADracks, plant, imagingBATTERYon the DC busSTATIC BYPASSmaintenance and overload pathDouble conversion: the load stays on the inverter,so an outage produces no transfer gap.

How a three phase double conversion UPS carries the load, and where the bypass sits.

9900CX models

The orderable configurations we supply and service:

ModelRatingPhase / VoltagePart numberStatus
Mitsubishi 9900CX 1050kVA (1000kW)1000 kW3ph in/out 480V·Current

Specifications

Phase3ph in/out
Voltage480V
Models1
StatusCurrent

Batteries and battery cabinets for the Mitsubishi Electric 9900CX

Battery strings and cabinets depend on the configuration and runtime. A worn string in the Mitsubishi Electric 9900CX can be rebuilt from the UPS battery block catalogue.

Mitsubishi Electric 9900CX service in Canada

We service the Mitsubishi Electric 9900CX across Canada: preventive maintenance, battery replacement and emergency repair, including units the manufacturer no longer supports. We are a Canadian UPS service and supply provider, working on three-phase systems since 2012.

Scheduled visits, battery work and fault response for these systems are covered by Mitsubishi UPS maintenance and repair in Canada.

Sizing, redundancy and custom builds

We engineer the solution: load and growth analysis, redundancy (N, N+1, 2N), runtime and battery sizing, paralleling and switchgear, and custom configurations where the standard catalogue doesn't fit. Because we supply every major brand, the 9900CX is one option we weigh on its merits, not the only answer.

Common questions

What is the Mitsubishi Electric 9900CX?

The Mitsubishi Electric 9900CX is a three-phase UPS for cloud, IT and colocation sites rated 1 MW.

Is the Mitsubishi Electric 9900CX discontinued?

No. Mitsubishi Electric lists the 9900CX as current.

Who services the Mitsubishi Electric 9900CX in Canada?

A Canadian UPS service and supply provider, in business since 2012, services the Mitsubishi Electric 9900CX across Canada: preventive maintenance, battery replacement and emergency repair, including discontinued units. Call 1 (438) 881-3363 or email info@threephaseups.ca.

Request a quote: Mitsubishi 9900CX

Tell us the application and we reply within 4 business hours with the sizing, the right system, the installation and a written quote. Three-phase installs usually need a licensed electrician, so let us know if you have one.

Do you have your own electrician?
Yearly preventive maintenance?

Or email info@threephaseups.ca · 1 (438) 881-3363