Toshiba · G9400
The Toshiba G9400 is a large online three-phase UPS rated 400 to 2,000 kVA at 480 V (1,050 to 1,750 kVA at 400 V).

Toshiba lists the G9400 as a current three-phase UPS.
Sources, checked October 3, 2026: Toshiba International, G9400 Series.
How a three phase double conversion UPS carries the load, and where the bypass sits.
The orderable configurations we supply and service:
| Model | Rating | Phase / Voltage | Part number | Status |
|---|---|---|---|---|
| Toshiba G9400 1200kVA (480V/60Hz) | 1200 kW | 3ph in/out 480V 60Hz | · | Current |
| Toshiba G9400 1600kVA (480V/60Hz) | 1600 kW | 3ph in/out 480V 60Hz | · | Current |
| Toshiba G9400 2000kVA (480V/60Hz) | 2000 kW | 3ph in/out 480V 60Hz | · | Current |
| Toshiba G9400 1050kVA (380-415V/50-60Hz global) | 1050 kW | 3ph in/out 380-415V 50/60Hz | · | Current |
| Toshiba G9400 1400kVA (380-415V/50-60Hz global) | 1400 kW | 3ph in/out 380-415V 50/60Hz | · | Current |
| Toshiba G9400 1750kVA (380-415V/50-60Hz global) | 1750 kW | 3ph in/out 380-415V 50/60Hz | · | Current |
The G9400 is Toshiba's megawatt UPS, 1200, 1600 and 2000 kVA at 480 V, built from 400 kW parallel power modules on Gen-7 CSTBT IGBTs. It holds about 97% online efficiency across the load range in a small footprint. The parallel-module design is inherently redundant: if a module faults, the rest stay online in double conversion as long as the load is within their capacity, instead of dropping the whole unit to bypass. Up to six systems parallel for capacity or N+x redundancy.
Each module carries a DC isolation contactor (CB2) as standard (many competitors make it an option) so the UPS can take a single module offline on a fan failure while the others keep supplying double-conversion power, and it meets the UL 1778 EPO isolation requirement without external relay schemes. 100 kAIC fuses are standard in the static bypass. A selectable High Efficiency Hibernate mode rests modules below ~50% load for up to ~3% more system efficiency, rotating them so they age evenly.
Sources: Toshiba, G9400 launch and G9400 value-added FAQ. Figures are Toshiba's published specifications.
Battery strings and cabinets depend on the configuration and runtime. A worn string in the Toshiba G9400 can be rebuilt from the UPS battery block catalogue.
We service the Toshiba G9400 across Canada: preventive maintenance, battery replacement and emergency repair, including units the manufacturer no longer supports. We are a Canadian UPS service and supply provider, working on three-phase systems since 2012.
Repairs on running and out-of-warranty units are handled under Toshiba G9400 service and repairs.
We engineer the solution: load and growth analysis, redundancy (N, N+1, 2N), runtime and battery sizing, paralleling and switchgear, and custom configurations where the standard catalogue doesn't fit. Because we supply every major brand, the G9400 is one option we weigh on its merits, not the only answer.
The Toshiba G9400 is a large online three-phase UPS rated 400 to 2,000 kVA at 480 V (1,050 to 1,750 kVA at 400 V).
No. Toshiba lists the G9400 as a current three-phase UPS.
A Canadian UPS service and supply provider, in business since 2012, services the Toshiba G9400 across Canada: preventive maintenance, battery replacement and emergency repair, including discontinued units. Call 1 (438) 881-3363 or email info@threephaseups.ca.
Tell us the application and we reply within 4 business hours with the sizing, the right system, the installation and a written quote. Three-phase installs usually need a licensed electrician, so let us know if you have one.