Vertiv / Liebert · EXM2
The Vertiv Liebert EXM2 is a double-conversion three-phase UPS rated 100 to 250 kVA (documented models).

Vertiv publishes the Liebert EXM2 as a current product in its brochure and user manual.
Sources, checked October 3, 2026: Vertiv, Liebert EXM2 brochure; Vertiv, Liebert EXM2 user manual 100-250 kVA (SL-71070).
How a three phase double conversion UPS carries the load, and where the bypass sits.
The orderable configurations we supply and service:
| Model | Rating | Phase / Voltage | Part number | Status |
|---|---|---|---|---|
| Liebert EXM2 100kVA | 100 kW | 3ph 3-wire in / 3ph out 208/220/480V | · | Current |
| Liebert EXM2 150kVA | 150 kW | 3ph 3-wire in / 3ph out 208/220/480V | · | Current |
| Liebert EXM2 200kVA | 200 kW | 3ph 3-wire in / 3ph out 208/220/480V | · | Current |
| Liebert EXM2 250kVA | 250 kW | 3ph 3-wire in / 3ph out 208/220/480V | · | Current |
The Liebert EXM2 is an online double-conversion three-phase UPS whose Dynamic Online mode reaches up to 98.8% efficiency while still compensating load harmonics, power factor and mains sags, high efficiency without giving up conditioning, and it carries an intelligent charger built to integrate with lithium-ion chemistries. A published deployment: TBC Bank in Tbilisi built a Tier III data centre sized to 240 kW IT load on a 250 kVA EXM2 in a 2N power configuration with 15 minutes of VRLA runtime, delivered in 36 weeks, about half the time of traditional construction. We supply, install and maintain the EXM2 the same way, scaled to your load and redundancy.
Sources: Vertiv, Liebert EXM2 brochure and TBC Bank case study (CS-10013). Figures are Vertiv’s published specifications.
An intelligent charger designed to work with lithium-ion batteries as well as VRLA. Battery kits that suit this platform are in the Vertiv / Liebert UPS battery catalogue.
We service the Vertiv Liebert EXM2 across Canada: preventive maintenance, battery replacement and emergency repair, including units the manufacturer no longer supports. We are a Canadian UPS service and supply provider, working on three-phase systems since 2012.
Scheduled visits, battery work and fault response for these systems are covered by Vertiv / Liebert UPS maintenance and repair in Canada.
We engineer the solution: load and growth analysis, redundancy (N, N+1, 2N), runtime and battery sizing, paralleling and switchgear, and custom configurations where the standard catalogue doesn't fit. Because we supply every major brand, the EXM2 is one option we weigh on its merits, not the only answer.
The Vertiv Liebert EXM2 is a double-conversion three-phase UPS rated 100 to 250 kVA (documented models).
No. Vertiv publishes the Liebert EXM2 as a current product in its brochure and user manual.
An intelligent charger designed to work with lithium-ion batteries as well as VRLA.
A Canadian UPS service and supply provider, in business since 2012, services the Vertiv Liebert EXM2 across Canada: preventive maintenance, battery replacement and emergency repair, including discontinued units. Call 1 (438) 881-3363 or email info@threephaseups.ca.
Tell us the application and we reply within 4 business hours with the sizing, the right system, the installation and a written quote. Three-phase installs usually need a licensed electrician, so let us know if you have one.
Brand names are trademarks of their owners and are used only to identify the equipment we service. We are not the manufacturer and are not affiliated with it.