EN · FR
Xtreme Power  ›  E91

Xtreme Power · E91

Xtreme Power E91 three-phase UPS

The XPC E91 is a compact facility three-phase UPS rated 10 to 40 kVA at 208/120 V.

Xtreme Power E91 three-phase UPS
Phase
3PH
Models
6
Lifecycle
Current model

XPC E91: key facts

Xtreme Power Conversion lists the E91 as current; it replaced the E90.

Sources, checked October 3, 2026: Xtreme Power Conversion, E91 10-20 kVA; Xtreme Power Conversion, E91 30-40 kVA.

THREE PHASE POWER PATH3 PHASE INPUT480 V or 208 V feedRECTIFIERAC to DCDC BUSregulatedINVERTERDC to clean ACCRITICAL LOADracks, plant, imagingBATTERYon the DC busSTATIC BYPASSmaintenance and overload pathDouble conversion: the load stays on the inverter,so an outage produces no transfer gap.

How a three phase double conversion UPS carries the load, and where the bypass sits.

E91 models

The orderable configurations we supply and service:

ModelRatingPhase / VoltagePart numberStatus
XPC E91 10kVA (208/120V three-phase)10 kW3ph in/out (3W+N+PE) 208Y/120V (or 220Y/127V)E91-10KCurrent
XPC E91 15kVA (208/120V three-phase)15 kW3ph in/out (3W+N+PE) 208Y/120V (or 220Y/127V)E91-15KCurrent
XPC E91 20kVA (208/120V three-phase)20 kW3ph in/out (3W+N+PE) 208Y/120V (or 220Y/127V)E91-20KCurrent
XPC E91 30kVA (208/120V three-phase)30 kW3ph in/out 208Y/120V (or 220Y/127V)E91-30KCurrent
XPC E91 30kVA extended-runtime (208/120V three-phase)30 kW3ph in/out 208Y/120V (or 220Y/127V)E91-30K4Current
XPC E91 40kVA (208/120V three-phase)40 kW3ph in/out 208Y/120V (or 220Y/127V)E91-40KCurrent

Specifications

Phase3ph in/out (3W+N+PE)
Voltage208Y/120V (or 220Y/127V)
Models6
StatusCurrent

Compact centralized three-phase

The E91 is a compact, centralized online double-conversion UPS (10 to 20 kVA (30 to 40 kVA on the sibling frame) at 208Y/120V) with the electronics and VRLA batteries in one cabinet, built for fixed-capacity sites that don't need a modular system. Its unity output power factor (kVA = kW) gives, per XPC, up to 25% more critical load than typical UPS platforms at the same kVA rating.

How efficient is the E91?

Efficiency runs up to 94% online and up to 98% in ECO mode (Energy Star 2.0), it rides through 110% for an hour, and it can be locked to 50 or 60 Hz as a frequency converter.

How long does the E91 run on its batteries?

At full load an E91-10K runs 11 minutes on its internal batteries and 113 minutes with two EBP09-5 external cabinets.

Does the E91 have a cUL listing for Canada?

It's UL, cUL, FCC and TAA compliant (the cUL listing matters for Canadian sites) with a 4.3-inch colour touch display and an SNMP/relay card slot.

Source: Xtreme Power Conversion, E91 product page. Figures are XPC's published specifications.

Batteries and battery cabinets for the XPC E91

Battery strings and cabinets depend on the configuration and runtime. Sealed VRLA blocks for Xtreme Power battery cabinets are in this sealed UPS battery range.

XPC E91 service in Canada

We service the XPC E91 across Canada: preventive maintenance, battery replacement and emergency repair, including units the manufacturer no longer supports. We are a Canadian UPS service and supply provider, working on three-phase systems since 2012.

Repairs on running and out-of-warranty units are handled under XPC E91 service and repairs.

Sizing, redundancy and custom builds

We engineer the solution: load and growth analysis, redundancy (N, N+1, 2N), runtime and battery sizing, paralleling and switchgear, and custom configurations where the standard catalogue doesn't fit. Because we supply every major brand, the E91 is one option we weigh on its merits, not the only answer.

Common questions

What is the XPC E91?

The XPC E91 is a compact facility three-phase UPS rated 10 to 40 kVA at 208/120 V.

Is the XPC E91 discontinued?

No. Xtreme Power Conversion lists the E91 as current; it replaced the E90.

Who services the XPC E91 in Canada?

A Canadian UPS service and supply provider, in business since 2012, services the XPC E91 across Canada: preventive maintenance, battery replacement and emergency repair, including discontinued units. Call 1 (438) 881-3363 or email info@threephaseups.ca.

Request a quote: Xtreme Power E91

Tell us the application and we reply within 4 business hours with the sizing, the right system, the installation and a written quote. Three-phase installs usually need a licensed electrician, so let us know if you have one.

Do you have your own electrician?
Yearly preventive maintenance?

Or email info@threephaseups.ca · 1 (438) 881-3363