APC / Schneider · Galaxy 7000
The MGE Galaxy 7000 is a double-conversion three-phase UPS rated 225 to 500 kVA at 400 V.

Sources, checked October 3, 2026: Schneider Electric Canada, MGE Galaxy 7000 500 kVA (G7TUPS500); Schneider Electric Canada, Galaxy 7000 range.
Schneider Electric discontinued the MGE Galaxy 7000: its Canadian site shows the 500 kVA model (G7TUPS500) as discontinued on August 29, 2023, with end of service scheduled for December 31, 2031, and points to the Galaxy VL range as the replacement. See the APC Galaxy VL page.
Units already installed keep working after the manufacturer's cut-off; what changes is parts and factory support. We maintain discontinued units and plan the replacement when it makes sense. How to plan the replacement of a discontinued three-phase UPS.
How a three phase double conversion UPS carries the load, and where the bypass sits.
The orderable configurations we supply and service:
| Model | Rating | Phase / Voltage | Part number | Status |
|---|---|---|---|---|
| Galaxy 7000 (legacy MGE) | 3ph in / 3ph out 400V | · | EOL |
Battery strings and cabinets depend on the configuration and runtime. When a string reaches end of life, replacement batteries for the MGE Galaxy 7000 are matched by cabinet and block type.
We service the MGE Galaxy 7000 across Canada: preventive maintenance, battery replacement and emergency repair, including units the manufacturer no longer supports. We are a Canadian UPS service and supply provider, working on three-phase systems since 2012.
Scheduled visits, battery work and fault response for these systems are covered by APC / Schneider UPS maintenance and repair in Canada.
We engineer the solution: load and growth analysis, redundancy (N, N+1, 2N), runtime and battery sizing, paralleling and switchgear, and custom configurations where the standard catalogue doesn't fit. Because we supply every major brand, the Galaxy 7000 is one option we weigh on its merits, not the only answer.
The MGE Galaxy 7000 is a double-conversion three-phase UPS rated 225 to 500 kVA at 400 V.
Schneider Electric discontinued the MGE Galaxy 7000: its Canadian site shows the 500 kVA model (G7TUPS500) as discontinued on August 29, 2023, with end of service scheduled for December 31, 2031, and points to the Galaxy VL range as the replacement.
Schneider Electric discontinued the MGE Galaxy 7000: its Canadian site shows the 500 kVA model (G7TUPS500) as discontinued on August 29, 2023, with end of service scheduled for December 31, 2031, and points to the Galaxy VL range as the replacement.
A Canadian UPS service and supply provider, in business since 2012, services the MGE Galaxy 7000 across Canada: preventive maintenance, battery replacement and emergency repair, including discontinued units. Call 1 (438) 881-3363 or email info@threephaseups.ca.
Tell us the application and we reply within 4 business hours with the sizing, the right system, the installation and a written quote. Three-phase installs usually need a licensed electrician, so let us know if you have one.
Brand names are trademarks of their owners and are used only to identify the equipment we service. We are not the manufacturer and are not affiliated with it.