APC / Schneider Galaxy VX three-phase UPS

The APC Galaxy VX is a large modular double-conversion three-phase UPS rated about 500 to 1,500 kW (400 V and 480 V models).

APC / Schneider Galaxy VX three-phase UPS
Phase
3PH
Models
17
Lifecycle
Current model

APC Galaxy VX: key facts

Schneider Electric lists the Galaxy VX as a current range. Some early part numbers were replaced by newer versions: GVX500K500HS was discontinued on July 5, 2023 and replaced by GVX500K500NHS. Schneider Electric also points owners of discontinued Symmetra PX 250 and 500 kW frames and of the Galaxy VM to Galaxy VX models.

Sources, checked October 3, 2026: Schneider Electric Canada, Galaxy VX range; Schneider Electric Canada, GVX500K500HS product page; Schneider Electric, EcoDataCenter customer story.

APC Galaxy VX three-phase UPS explained

2:22. The APC Galaxy VX is Schneider Electric's large modular double-conversion three-phase UPS, from about 500 to 1,500 kW in 400 and 480 volt models. This video covers the field results Schneider publishes, the part-number change on the 500 kVA frame, and its role as the named replacement path for the Symmetra PX large frames and Galaxy VM.

Chapters

  1. 0:00 What is the APC Galaxy VX?
  2. 0:14 What does modular mean here?
  3. 0:30 Which batteries does it take?
  4. 0:53 What does it look like in the field?
  5. 1:16 Do the part numbers move?
  6. 1:32 Is it current?
  7. 1:54 Who is it for?
  8. 2:05 Request a quote
Transcript

0:00 What is the APC Galaxy VX? What is the APC Galaxy VX? It is Schneider Electric's large modular double-conversion three-phase UPS, from about 500 to 1,500 kilowatts, in 400 and 480 volt models.

0:14 What does modular mean here? What does modular mean here? Capacity lives in power modules inside a large frame, so capacity and serviceability are designed around the module, you add capability by adding modules, and the range carries eConversion and lithium-ion battery options.

0:30 Which batteries does it take? Which batteries does it take? External battery systems, with lithium-ion options among them, so the battery plant is specified with the room. How efficient is it? Up to 99 percent in eConversion mode, as Schneider Electric publishes. And like the rest of the Galaxy V series, eConversion has been Schneider Electric's factory default since 2022.

0:53 What does it look like in the field? What does it look like in the field? Schneider's published customer story features EcoDataCenter in Falun, Sweden: four Galaxy VX units at 1,250 kilowatts each, with the option to operate at 99 percent efficiency in eConversion. The site reuses its waste heat back to the local grid. Those are Schneider's published numbers, not our claim.

1:16 Do the part numbers move? Do the part numbers move? On this range they do. Schneider Electric discontinued the early GVX500K500HS on July 5, 2023, and replaced it with GVX500K500NHS.

1:32 Is it current? Is it current? Yes. Schneider Electric lists the Galaxy VX as a current range. It also points owners of the discontinued Symmetra PX 250 and 500 kilowatt frames, and owners of the Galaxy VM, to Galaxy VX models, which makes the VX Schneider Electric's named replacement path for those frames.

1:54 Who is it for? Who is it for? Large data centres, cloud and colocation sites, at the 500 to 1,500 kilowatt scale, where a large modular frame carries the hall.

2:05 Request a quote If you are sizing one, request a quote at threephaseups.ca.

Maintenance visit checklist

What does a maintenance visit check on an APC Galaxy VX?

2:13. On an APC Galaxy VX the operator's part is read-only: mimic LEDs and the alarm list, load percentage and mode, room temperature and clear air intakes, and the UPS log exported before any reset. The visit covers fans, filters and capacitors; battery plants are replaced string by string; and the manual's maintenance-bypass and locked-in-bypass rules set the visit's ground rules. Source: Schneider's Galaxy VX operation manual 990-5452N (V13, 7/2025).

Chapters

  1. 0:00 What does a maintenance visit check on an APC Galaxy VX?
  2. 0:12 What is on you?
  3. 0:28 What does the visit look for?
  4. 0:43 Which alarms show the wear first?
  5. 0:57 Which battery alarms matter for planning?
  6. 1:17 How do the batteries get replaced?
  7. 1:28 What about the bypass?
  8. 1:44 What is the boundary?
  9. 1:56 Request a quote
Transcript

0:00 What does a maintenance visit check on an APC Galaxy VX? What does a maintenance visit check on an APC Galaxy VX? The split: your part is read-only, from the front, and everything else belongs to a scheduled visit by qualified service staff.

0:12 What is on you? What is on you? Read the mimic lights and the alarm list, record the load percentage and the mode, and check the room temperature and that nothing blocks the air intakes. And photograph or write down the active alarms and the event log before anyone resets anything.

0:28 What does the visit look for? What does the visit look for? The parts with a clock: fans, filters and capacitors, covered before they turn into alarms. The Galaxy VX operation manual gives no replacement intervals for those parts; the visit is how the wear gets caught.

0:43 Which alarms show the wear first? Which alarms show the wear first? Restricted air flow is rated critical: a clogged air filter or another obstacle, so room cooling and airflow are the first checks. Fan inoperable is a warning: fan redundancy is lost.

0:57 Which battery alarms matter for planning? Which battery alarms matter for planning? Battery condition is poor means capacity is below 50 percent, and the manual says the batteries should be replaced. Battery breakers tripped means the system stopped a deep discharge, and the manual's action is to close the battery breakers manually. If it happens again, call before closing them.

1:17 How do the batteries get replaced? How do the batteries get replaced? Large VX battery plants are usually replaced string by string, with blocks matched to the installed Schneider string, planned before outage season.

1:28 What about the bypass? What about the bypass? System operation mode, Maintenance Bypass, means the load is on the maintenance breaker, the MBB, on unconditioned utility power. And System locked in bypass operation is critical: more than 10 transfers within 1 minute.

1:44 What is the boundary? What is the boundary? Everything else, including breakers, power cabinets and batteries, is technician work. Lost redundancy keeps the load but loses the margin the system was bought for.

1:56 Request a quote If your VX is due for a visit, request a quote at threephaseups.ca.

THREE PHASE POWER PATH3 PHASE INPUT480 V or 208 V feedRECTIFIERAC to DCDC BUSregulatedINVERTERDC to clean ACCRITICAL LOADracks, plant, imagingBATTERYon the DC busSTATIC BYPASSmaintenance and overload pathDouble conversion: the load stays on the inverter,so an outage produces no transfer gap.

How a three phase double conversion UPS carries the load, and where the bypass sits.

Galaxy VX models

The orderable configurations we supply and service:

ModelRatingPhase / VoltagePart numberStatus
Galaxy VX 500 kVA 400V500 kW3ph in / 3ph out 400VGVX500K500HSCurrent
Galaxy VX 500 kVA scalable to 750 kVA 400V500 kW3ph in / 3ph out 400VGVX500K750HSCurrent
Galaxy VX 500 kVA scalable to 1000 kVA 400V500 kW3ph in / 3ph out 400VGVX500K1000HSCurrent
Galaxy VX 625 kVA 400V625 kW3ph in / 3ph out 400VGVX625K625HSCurrent
Galaxy VX 625 kVA scalable to 1000 kVA 400V625 kW3ph in / 3ph out 400VGVX625K1000HSCurrent
Galaxy VX 500 kVA N+1 redundant (750 frame)500 kW3ph in / 3ph out 400VGVX750K500HSCurrent
Galaxy VX 750 kVA 400V750 kW3ph in / 3ph out 400VGVX750K750HSCurrent
Galaxy VX 750 kVA scalable to 1000 kVA 400V750 kW3ph in / 3ph out 400VGVX750K1000HSCurrent
Galaxy VX 750 kVA N+1 redundant (1000 frame)750 kW3ph in / 3ph out 400VGVX1000K750HSCurrent
Galaxy VX 1000 kVA 400V1000 kW3ph in / 3ph out 400VGVX1000K1000HSCurrent
Galaxy VX 1000 kVA scalable to 1500 kVA 400V1000 kW3ph in / 3ph out 400VGVX1000K1500HSCurrent
Galaxy VX 1000 kVA N+1 redundant (1250 frame)1000 kW3ph in / 3ph out 400VGVX1250K1000HSCurrent
Galaxy VX 1250 kVA 400V1250 kW3ph in / 3ph out 400VGVX1250K1250HSCurrent
Galaxy VX 1250 kVA scalable to 1500 kVA 400V1250 kW3ph in / 3ph out 400VGVX1250K1500HSCurrent
Galaxy VX 1250 kVA N+1 redundant (1500 frame)1250 kW3ph in / 3ph out 400VGVX1500K1250HSCurrent
Galaxy VX 1500 kVA 400V1500 kW3ph in / 3ph out 400VGVX1500K1500HSCurrent
Galaxy VX 1500 kVA N+1 redundant (1750 frame)1500 kW3ph in / 3ph out 400VGVX1750K1500HSCurrent

Specifications

Phase3ph in / 3ph out
Voltage400V
Models17
StatusCurrent

Large-scale efficiency & a field result

The Galaxy VX is a modular three-phase UPS for large data centres, cloud and colocation, roughly 500 to 1500 kW, with eConversion and lithium-ion battery options. A published field result: EcoDataCenter in Falun, Sweden runs four Galaxy VX at 1250 kW each with the option to operate at 99% efficiency in eConversion, and reports a facility 1.15 PUE at 2N redundancy with reuse of waste heat. The freed energy can be diverted to client load. We size, supply, install and maintain the VX at this scale, and weigh it against the alternatives for your load profile and redundancy target.

Sources: Schneider Electric, EcoDataCenter customer story and eConversion default mode. Figures are Schneider’s published specifications.

Batteries and battery cabinets for the APC Galaxy VX

External battery systems, with lithium-ion options. Battery kits that suit this platform are in the APC / Schneider UPS battery catalogue.

APC Galaxy VX service in Canada

We service the APC Galaxy VX across Canada: preventive maintenance, battery replacement and emergency repair, including units the manufacturer no longer supports. We are a Canadian UPS service and supply provider, working on three-phase systems since 2012.

Repairs on running and out-of-warranty units are handled under APC Galaxy VX service and repairs.

Sizing, redundancy and custom builds

We engineer the solution: load and growth analysis, redundancy (N, N+1, 2N), runtime and battery sizing, paralleling and switchgear, and custom configurations where the standard catalogue doesn't fit. Because we supply every major brand, the Galaxy VX is one option we weigh on its merits, not the only answer.

Common questions

What is the APC Galaxy VX?

The APC Galaxy VX is a large modular double-conversion three-phase UPS rated about 500 to 1,500 kW (400 V and 480 V models).

Is the APC Galaxy VX discontinued?

No. Schneider Electric lists the Galaxy VX as a current range. Some early part numbers were replaced by newer versions: GVX500K500HS was discontinued on July 5, 2023 and replaced by GVX500K500NHS.

What batteries does the APC Galaxy VX use?

External battery systems, with lithium-ion options.

Who services the APC Galaxy VX in Canada?

A Canadian UPS service and supply provider, in business since 2012, services the APC Galaxy VX across Canada: preventive maintenance, battery replacement and emergency repair, including discontinued units. Call 1 (438) 881-3363 or email info@threephaseups.ca.

Request a quote: APC / Schneider Galaxy VX