Vertiv / Liebert · APM2
The Vertiv Liebert APM2 is a modular, transformer-free double-conversion three-phase UPS rated 10 to 150 kVA/kW at 208/220 V and 20 to 600 kVA/kW at 480/415 V.

Vertiv lists the Liebert APM2 as a current product family in Canada.
Sources, checked October 3, 2026: Vertiv Canada, Liebert APM2 UL UPS 208V; Vertiv, Liebert APM2 10-600 kW brochure (SL-71311).
2:19. The Liebert APM2 is Vertiv's modular, transformer-free double-conversion three-phase UPS, from 10 to 150 kVA at 208/220 V and 20 to 600 kVA at 480/415 V. This video covers the hot-swap modules and MTTR, the published efficiency modes, unity power factor output, the 600 mm all-in-one row, and how the older APM relates to it.
0:00 What is the Liebert APM2? What is the Liebert APM2? It is Vertiv's modular, transformer-free double-conversion three-phase UPS, from 10 to 150 kVA at 208 or 220 volts, and 20 to 600 kVA at 480 or 415 volts.
0:18 What does modular mean here? What does modular mean here? Hot-swappable power modules, and Vertiv publishes a mean time to repair under half an hour. The converter design is three-level IGBT with hybrid silicon carbide.
0:30 Which batteries does it take? Which batteries does it take? Internal VRLA or lithium-ion batteries on the smaller frames, or external battery cabinets.
0:38 How efficient is it? How efficient is it? Vertiv publishes 97.5 percent peak in double conversion, up to 98.8 percent in Dynamic Online, and up to 99 percent in ECO mode, in the modes published for this family.
0:53 And the output? And the output? Unity power factor: kilowatts equal kVA, so the frame's rating is real power for IT load. A single unit scales to 600 kilowatts, and a parallel system of four units reaches 2.4 megawatts.
1:08 And the footprint? And the footprint? The 10 to 120 kVA frame packs power, maintenance bypass and battery into a 600 millimetre width, so a row-based site gets everything in one strip, and Vertiv claims up to about 55 percent footprint saving.
1:24 And the older APM? And the older APM? Vertiv still lists the 208 volt APM family; the international 380 to 415 volt versions are legacy. The APM2 is the newer platform covering the wider range, and Vertiv lists it as current in Canada, so a 208 volt APM site stays on a listed family.
1:46 Who is it for? Who is it for? Sites that want modular, transformer-free protection from a single rack row up to a mid-size data hall, in the 10 to 600 kVA range, at 208, 220, 480 or 415 volts. If you are sizing one, request a quote at threephaseups.ca.
2:05. On a Liebert APM2 the operator's part is the touchscreen and the front of the room: alarm text, the time, room conditions; the Silence button stops the sound but not the condition. The visit covers the wear parts and tests the battery settings the manual defines: a low pre-warning adjustable 2-60 minutes (5 default) and an end-of-discharge voltage of 1.60-1.85 V per cell on VRLA. Safety timings: battery terminals stay live after shutdown and the DC bus needs 30 minutes to discharge. Source: Vertiv's APM2 user manual SL-71948.
0:00 What does a maintenance visit check on a Liebert APM2? What is checked during a maintenance visit on a Vertiv Liebert APM2? The split: your part is read-only, from the touchscreen and the front, and everything inside the power cabinets belongs to a scheduled visit.
0:12 What is on you? What is on you? Read the alarm text on the touchscreen and note the time, and check the room conditions from the front. The Silence button stops the sound, but the message stays until the condition is corrected. Silencing is not clearing.
0:26 What does the visit look for? What does the visit look for? The wear parts, and Vertiv's own replacement table for them: fans with a life of not less than 7 years, replaced at five to six and inspected yearly; air filters with a life of 1-3 years, replaced at one to two.
0:42 What does that table say about batteries? What does that table say about batteries? A five-year-design VRLA battery is replaced at three to four years; a ten-year-design at 6-8 years. Vertiv's caveat: those are estimates, and other conditions need a service engineer's assessment.
0:57 What do you test between visits? What do you test between visits? That the battery low pre-warning lands where you set it: the manual makes it adjustable from 2-60 minutes, 5 minutes by default, with the end-of-discharge voltage settable from one point six zero to one point eight five volts per cell on sealed lead-acid batteries.
1:16 What are the safety timings? What are the safety timings? After any shutdown, the battery terminals still carry hazardous voltage, and the internal DC bus capacitors need 30 minutes to discharge.
1:26 And after a fault shutdown? And after a fault shutdown? Clear the cause shown by the alarm message first, then use Reset Fault and restart. If the shutdown came from overtemperature, the rectifier restarts by itself 5 minutes after the signal disappears.
1:40 What is the boundary? What is the boundary? Everything else, including breakers, power cabinets and batteries, is technician work. If a Liebert APM2 is due for a visit, request a quote at threephaseups.ca.
How a three phase double conversion UPS carries the load, and where the bypass sits.
The orderable configurations we supply and service:
| Model | Rating | Phase / Voltage | Part number | Status |
|---|---|---|---|---|
| Liebert APM2 10kW (208V) | 10 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 10 kW 208V | Current |
| Liebert APM2 20kW (208V) | 20 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 20 kW 208V | Current |
| Liebert APM2 25kW (208V) | 25 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 25 kW 208V | Current |
| Liebert APM2 30kW (208V) | 30 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 30 kW 208V | Current |
| Liebert APM2 40kW (208V) | 40 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 40 kW 208V | Current |
| Liebert APM2 45kW (208V) | 45 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 45 kW 208V | Current |
| Liebert APM2 50kW (208V) | 50 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 50 kW 208V | Current |
| Liebert APM2 60kW (208V) | 60 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 60 kW 208V | Current |
| Liebert APM2 75kW (208V) | 75 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 75 kW 208V | Current |
| Liebert APM2 80kW (208V) | 80 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 80 kW 208V | Current |
| Liebert APM2 90kW (208V) | 90 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 90 kW 208V | Current |
| Liebert APM2 100kW (208V) | 100 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 100 kW 208V | Current |
| Liebert APM2 120kW (208V) | 120 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 120 kW 208V | Current |
| Liebert APM2 140kW (208V) | 140 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 140 kW 208V | Current |
| Liebert APM2 150kW (208V) | 150 kW | 3ph 3-wire+N+PE in/out 208/220V | APM2 150 kW 208V | Current |
| Liebert APM2 20kW (480V) | 20 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 20 kW 480V | Current |
| Liebert APM2 30kW (480V) | 30 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 30 kW 480V | Current |
| Liebert APM2 40kW (480V) | 40 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 40 kW 480V | Current |
| Liebert APM2 50kW (480V) | 50 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 50 kW 480V | Current |
| Liebert APM2 60kW (480V) | 60 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 60 kW 480V | Current |
| Liebert APM2 80kW (480V) | 80 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 80 kW 480V | Current |
| Liebert APM2 90kW (480V) | 90 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 90 kW 480V | Current |
| Liebert APM2 100kW (480V) | 100 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 100 kW 480V | Current |
| Liebert APM2 120kW (480V) | 120 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 120 kW 480V | Current |
| Liebert APM2 150kW (480V) | 150 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 150 kW 480V | Current |
| Liebert APM2 180kW (480V) | 180 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 180 kW 480V | Current |
| Liebert APM2 200kW (480V) | 200 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 200 kW 480V | Current |
| Liebert APM2 225kW (480V) | 225 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 225 kW 480V | Current |
| Liebert APM2 250kW (480V) | 250 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 250 kW 480V | Current |
| Liebert APM2 300kW (480V) | 300 kW | 3ph 3-wire+N+PE in/out 380/400/415/480V | APM2 300 kW 480V | Current |
| Liebert APM2 300kW (480V high-frame) | 300 kW | 3ph 3-wire+PE in/out 480V | APM2 300 kW 480V (300-600 kW frame) | Current |
| Liebert APM2 360kW (480V) | 360 kW | 3ph 3-wire+PE in/out 480V | APM2 360 kW 480V | Current |
| Liebert APM2 400kW (480V) | 400 kW | 3ph 3-wire+PE in/out 480V | APM2 400 kW 480V | Current |
| Liebert APM2 420kW (480V) | 420 kW | 3ph 3-wire+PE in/out 480V | APM2 420 kW 480V | Current |
| Liebert APM2 480kW (480V) | 480 kW | 3ph 3-wire+PE in/out 480V | APM2 480 kW 480V | Current |
| Liebert APM2 500kW (480V) | 500 kW | 3ph 3-wire+PE in/out 480V | APM2 500 kW 480V | Current |
| Liebert APM2 540kW (480V) | 540 kW | 3ph 3-wire+PE in/out 480V | APM2 540 kW 480V | Current |
| Liebert APM2 600kW (480V) | 600 kW | 3ph 3-wire+PE in/out 480V | APM2 600 kW 480V | Current |
The Liebert APM2 is an online modular three-phase UPS (208/220 V and 480/415 V) built on three-level IGBT and hybrid silicon-carbide converters for 97.5% peak double-conversion efficiency, up to 98.8% in Dynamic Online and up to 99% in ECO mode. Output is unity power factor (kW = kVA). A single unit scales to 600 kW, up to 2.4 MW with 4 units in parallel, with N+1 hot-swappable power modules and an MTTR under half an hour. The 10 to 120 kVA frame fits power modules, internal batteries and an optional internal maintenance bypass into a 600 mm width, Vertiv claims up to ~55% footprint saving, with internal VRLA or lithium-ion batteries, 65 kA short-circuit withstand, and OSHPD seismic pre-approval.
Source: Vertiv, Liebert APM2 brochure (SL-71311). Figures are Vertiv’s published specifications.
Internal VRLA or lithium-ion batteries on the smaller frames, or external battery cabinets. Battery kits that suit this platform are in the Vertiv / Liebert UPS battery catalogue.
We service the Vertiv Liebert APM2 across Canada: preventive maintenance, battery replacement and emergency repair, including units the manufacturer no longer supports. We are a Canadian UPS service and supply provider, working on three-phase systems since 2012.
Planned visits and emergency calls are arranged through on-site service for the Vertiv Liebert APM2.
We engineer the solution: load and growth analysis, redundancy (N, N+1, 2N), runtime and battery sizing, paralleling and switchgear, and custom configurations where the standard catalogue doesn't fit. Because we supply every major brand, the APM2 is one option we weigh on its merits, not the only answer.
The Vertiv Liebert APM2 is a modular, transformer-free double-conversion three-phase UPS rated 10 to 150 kVA/kW at 208/220 V and 20 to 600 kVA/kW at 480/415 V.
No. Vertiv lists the Liebert APM2 as a current product family in Canada.
Internal VRLA or lithium-ion batteries on the smaller frames, or external battery cabinets.
A Canadian UPS service and supply provider, in business since 2012, services the Vertiv Liebert APM2 across Canada: preventive maintenance, battery replacement and emergency repair, including discontinued units. Call 1 (438) 881-3363 or email info@threephaseups.ca.
Tell us the application and we reply within 4 business hours with the sizing, the right system, the installation and a written quote. Three-phase installs usually need a licensed electrician, so let us know if you have one.
Brand names are trademarks of their owners and are used only to identify the equipment we service. We are not the manufacturer and are not affiliated with it.